A laboratory centrifuge is an essential piece of equipment for separating mixtures based on density differences. However, operating and maintaining centrifuges requires proper training to ensure safety. This article provides a detailed overview on installing, using, and servicing centrifuges with safety as the top priority.

6384050512993473779774507.png

 

Table of Contents

  • Introduction
  • Installation Requirements
  • Safe Operation Procedures
  • Routine Maintenance Tasks
  • Recommendations for Safe Practices
  • When Accidents Occur
  • Choosing the Right Centrifuge Tubes from Esco
  • Conclusion

Common Applications of Laboratory Centrifuges

Centrifugation is widely used in laboratories for separating particles suspended in solutions based on density. Some key applications include sedimentation of cells, viruses, and organelles, isolating DNA, RNA, proteins and lipids, and separating blood components like serum from whole blood Thermo Fisher Scientific. Tabletop centrifuges are commonly found in diagnostic labs, hospitals, biotech facilities for various separating procedures.

Installation Requirements

To ensure optimum performance, centrifuges must be placed on a sturdy, level surface allowing adequate clearance and away from heat sources or windows. Follow manufacturer guidelines for electrical, environmental, and loading requirements. Inspect rotors for damage and clean drive shafts before use. Only load rotors symmetrically to maintain balance.

Safe Operation Procedures

Always secure rotors tightly, do load more than recommended, and inspect tubes for cracks. Use safety cups with infectious samples. Monitor for unusual noises and wait until full speed is reached before leaving. Close lids during runs and wait 10 minutes after stopping before opening Lab Manager.

Routine Maintenance Tasks

Maintenance such as cleaning, lubrication, inspection prevents inefficiencies and hazards. Follow the schedule provided in Table 1 for tasks before, after, and yearly. Perform calibration testing annually and sterilize contaminated parts according to guidelines.

Recommendations for Safe Practices

Some tips include using plastic instead of glass tubes, properly fitting tubes in adapters, and handling samples in a biosafety cabinet. Wait 30 minutes after a spill and decontaminate immediately with bleach or ethanol solutions.

When Accidents Occur

If a tube breaks during operation, wait at least 30 minutes before opening to allow aerosols to settle. Notify appropriate personnel and follow spill response procedures. Incidents must be properly documented and reviewed to prevent future accidents.

Choosing the Right Centrifuge Tubes from Esco

Esco offers high-quality centrifuges and accessories and is a leader in laboratory equipment solutions. Their products are optimized for performance, safety and require minimal maintenance. Contact an Esco representative for guidance on purchasing, servicing or repair needs.

Conclusion

With proper training, established safety protocols and timely maintenance of centrifuges, laboratories can minimize risks and obtain consistent, reliable experimental results. Following guidelines detailed in this guide is essential for working safely with these important pieces of equipment.